Logochromatographyshopneu
 Process Chrom. Systems

We offer the most competitive prep and industrial production scale HPLC system in the market

The Product Range

Down-load Brochure:Chromatography Systems WEB

NewStyle Unitary High Pressure Analytical Chromatography System 4101

System Layout

HLCC_NS4101

Performance Characteristics

The system NS 4101 comprises of a chromatography pump (Flow rate 10 ml/min) combined with a uv to visible detector for isocratic runs for analysis and semi prep – operations. It is a very stable system for routine analysis in a production lab. Sample injection is via manual injection valve. Column type selection at your own choice.

System Configuration

Article No.

Description

Quantity

AS 10001

Unitary high pressure analytical HPLC system complete

1

CH-E90005

1. NP7001 10 ml/min high pressure constant current infusion pump

1

CH-E90305

2. NU3001 UV-Vis. Detector

1

CH-S00810

3. Flow cell

1

CH-S02300

4. Start-up installation kit

1

CH-E92100

5. Manual injection valve

1

 

6. Analytical column of your own choice

1

CH-E90950

7. EasyChrom - 1000

1

CH-E90980

8. Solvent tray

1


Up to menu

Down to menu

NewStyle Binary High Pressure Analytical Chromatography System 4201

System Layout

HLCC_NS4201

Performance Characteristics

The System NS4201 is very competitive analytical binary system comprising of two HPLC piston pumps and a UV – visible detector, a manual injection valve and static mixer. For gradient and isocratic operation in a routine analytical lab operation.

System Configuration

Article No.

Description

Quantity

AS 20001

Binary high pressure analytical HPLC system complete

1

CH-E90005

1. NP7001 10 ml/min high pressure constant current infusion pump

2

CH-E90305

2. NU3001 UV-Vis. Detector

1

CH-S00810

3. Flow cell

1

CH-S02300

4. Start-up installation kit

1

CH-E92100

5. Manual injection valve

1

 

6. Analytical column of your own choice

1

CH-E90950

7. EasyChrom - 1000

1

CH-E90980

8. Solvent tray

1


Up to menu

Down to menu

NewStyle Binary High Pressure Semi-Prep Chromatography System 4205

System Layout

Binary Semi-Prep system NS4205WEB

Performance Characteristics

The system NS 4205 is a binary semi-prep HPLC System with a constant flow 50 ml / min flow rate. Sample injection is through a manual injection valve and a semi-prep static mixer.  The UV – visible detector has a semi prep – flow cell.  It is ideal for gradient and isocratic mode HPLC.  It is ideal for process research and peptide purification

System Configuration

Article No.

Description

Quantity

AS 20005

Binary high pressure semi-preparative HPLC system complete

1

CH-E90010

1. NP7005 C 50 ml/min high pressure constant current infusion pump

2

CH-E90310

2. NU3000C UV-Vis. Detector

1

CH-S00820

3. Flow cell

1

CH-S02305

4. Start-up installation kit

1

CH-E92250

5. INJ-SP Prep Injection valve

1

CH-E92350

6. 10 ml loop

1

CH-E92020

7. Semi prep dynamic mixer

1

 

8. Semi Prep column of your own choice 10 mm id

1

CH-E90950

9. EasyChrom - 1000

1

CH-S00120

10. In-line filter set

1

CH-E90980

11. Solvent tray

1


Up to menu

Down to menu

NewStyle Binary Separation & Purification System LS 2010 for Process Research

System Layout

HLCC_LS2010

Performance Characteristics

The System LS 2010 is a preparative binary liquid phase purification-separation HPLC plant with flow rate of 100 ml/ min.  For 10 to 50 mm id pre-packed column.  The system is supplied with a 50 mm id Dynamic axial compressed column. The detector is a prep- UV-visible detector.

System Configuration

Article No.

Description

Quantity

LS 20010.05

Binary preparative liquid phase separation & purification system for laboratories complete

1

CH-E90015

1. NP7010C 100 ml/min high pressure constant current infusion pump

2

CH-E90310

2. NU3000C UV-Vis. Detector

1

CH-S00820

3. Flow cell

1

CH-S02500

4. Start-up installation kit

1

CH-E92250

5. INJ-SP Prep Injection valve

1

CH-E92355

6. 20 ml loop

1

CH-E92020

7. Semi prep dynamic mixer

1

 

8. Semi Prep column of your own choice 20 mm id

1

CH-E90950

9. EasyChrom - 1000

1

CH-S00130

10. In-line filter set

1

CH-E90980

11. Solvent tray

1

CH-E90990

12. Network controller

1

CH-E90605

13. DAC-HB50 dynamic axial compression column

1


Up to menu

Down to menu

NewStyle Ternary Large Scale Preparative Separation and Purification System with 80 mm ID Column

System Layout

Similar as below

Performance Characteristics

The System PS 30030 is a ternary preparative separation purification system with flow rates up to 300 ml/ min.  The system utilizes either manual injection or injection through ternary HPLC pump.  The peaks are collected via a UV- visible detector . With the system comes with a 80 mm id DAC column

System Configuration

Article No.

Description

Quantity

PS 30030.08

Ternary preparative liquid phase separation & purification system for large scale chromatography complete

1

CH-E90020

1. NP7030C 300 ml/min high pressure constant current infusion pump

3

CH-E90310

2. NU3000C UV-Vis. Detector

1

CH-S00840

3. Flow cell

1

CH-S02505

4. Start-up installation kit

1

CH-E92300

5. INJ-SP Prep Injection valve

1

CH-E92355

6. 20 ml loop

1

CH-E92030

7. dynamic mixer

1

CH-E90950

8. EasyChrom - 1000

1

CH-S00130

9. In-line filter set

1

CH-E90990

10. Network controller

1

CH-E90610

11. DAC-HB80 dynamic axial compression column

1


Up to menu

Down to menu

Newstyle Ternary Large Scale Preparative Separation and Purification System with 100 mm ID Column

System Layout

HLCC_PS30060.10

Performance Characteristics

Ternary preparative high pressure purification and separation system with excellent price/performance ratio.  Max. Flow rate is 600 ml/min. Injection is via ternary HPLC pump. Large 20 ml injection loop. 100 mm id DAC Column

System Configuration

Article No.

Description

Quantity

PS 30060.10

Ternary preparative liquid phase separation & purification system for large scale chromatography complete

1

CH-E90025

1. NP7060C 600 ml/min high pressure constant current infusion pump

3

CH-E90310

2. NU3000C UV-Vis. Detector

1

CH-S00840

3. Flow cell

1

CH-S02505

4. Start-up installation kit

1

CH-E92300

5. INJ-SP Prep Injection valve

1

CH-E92355

6. 20 ml loop

1

CH-E92030

7. dynamic mixer

1

CH-E90950

8. EasyChrom - 1000

1

CH-S00150

9. In-line filter set

1

CH-E90990

10. Network controller

1

CH-E90615

11. DAC-HB100 dynamic axial compression column

1


Up to menu

Down to menu

Newstyle Ternary Large Scale Preparative Separation and Purification System with 150 mm ID Column

System Layout

HLCC_PS30100.15

Performance Characteristics

Three large prep HPLC pumps (Flow rate: max. 1000 ml/ min) for isocratic and gradient mode of operation. One prep sample injection pump, static mixer and UV – visible detector. DAC column 150 mm id.

System Configuration

Article No.

Description

Quantity

PS 30100.15

Ternary preparative liquid phase separation & purification system for large scale chromatography complete

1

CH-E90030

1. NP7100C 1000 ml/min high pressure constant current infusion pump

3

CH-E90310

2. NU3000C UV-Vis. Detector

1

CH-S00850

3. Flow cell

1

CH-S02505

4. Start-up installation kit

1

CH-E92030

5. dynamic mixer

1

CH-E90950

6. EasyChrom - 1000

1

CH-S00180

7. In-line filter set

1

CH-E90990

8. Network controller

1

CH-E90620

9. DAC-HB150 dynamic axial compression column

1


Up to menu

Down to menu

Newstyle Ternary Large Scale Preparative Separation and Purification System with 200 mm ID Column

System Layout

HLCC_CS30300.20

Performance Characteristics

Ternary industrial scale purification & separation system comprising of two large prep HPLC pumps (Flow rate: max. 3000 ml/ min) for isocratic and gradient mode of operation. One prep sample injection pump, static mixer and UV – visible detector. DAC column 200 mm id.

 

System Configuration

Article No.

Description

Quantity

PS 30300.20

Ternary preparative liquid phase separation & purification system for commercial scale chromatography complete

1

CH-E90035

1. NP7300C 3000 ml/min high pressure constant current infusion pump

3

CH-E90310

2. NU3000C UV-Vis. Detector

1

CH-S00870

3. Flow cell

1

CH-S02510

4. Start-up installation kit

1

CH-E92090

5. dynamic mixer for commercial scale

1

CH-E90950

6. EasyChrom - 1000

1

CH-S00200

7. In-line filter set

1

CH-E90990

8. Network controller

1

CH-E90625

9. DAC-HB200 dynamic axial compression column

1


Up to menu

Down to menu

Industrial Scale Purification & Separation System with columns  ranging from 150 mm up to 2000 mm id

System Layout

HLCC_CS Prep Plants

Performance Characteristic

Industrial Chromatography system includes large DAC column connected with prep HPLC system comprising of the following components infusion, slurry mixing, detection, injection, fraction collection, control and data processing.

Industrial Chromatography system have to b e customized to the individual customer needs.  The column diameter vary from 150 mm to 2000 mm depending on requirements. We can also supply different pump system. We can also supply system with high pressure piston pumps with flow rates ranging from 10, 20, 40, 80 and 120 l / minutes.

 

 

 

© by LCC 1995 -2016 All rights reserved
 Chromatographyshop is a division of LCC Engineering & Trading GmbH, CH-4622 Egerkingen, Switzerland.
Collaboration partners in various countries
Our Company Profile and Summary Product List 2015
Unser Firmenprofil und Produktzusammenfassung 2015
      Our Terms and Conditions

Sample Preparation Tools

[Sample  Preparation]
[MatrixEx]
[QuEChERS]
[SPE]
[Syringe Filters]
[Inert RSA  Glass Vials]
[Flash Chromatography]

General Issues

[Chromatogr. Shop Home]
[Newsletter Archive]
[Our Services & Company]
[Terms & Conditions]
[Mobile Phone]

 Bonuses for you

[Special Deals for you]

Seminars & Workshops

[Knowledge Education]
[Seminars & Workshops]

Analytical Scale Chromatography

[Analytical Columns]
[ACE & ACE  Excel Columns]
[ACE Ultra Core]
[Microsolv Cogent Column]
[Capcell Shiseido]
[Daicel / Chiral Technologies]
[GL Science  Inertsil]
[Hichrom Columns]
[Imtakt Column]
[Kromasil Akzo Nobel]
[Mitsubishi MCI-Gel]
[Merck Lichro...]
[Macherey &  Nagel]
[Princeton  Chromatography]
[PolyLC  Columns]
[SieLC Primesep]
[Capcell Shiseido]
[Ultron by Shinwa]
[Welch  Materials]
[Zirchrom]
[Agilent Zorbax]

Knowledge Tools for Chromatographers

[Knowledge Education]
[Definition of  Terms Used]
[Separation Mechanism]
[Solvent  Selection]
[Buffers for  LC.]
[Column &  Material Care]
[Prep & Process Columns]
[Analytical  Columns]
[HPLC- to-UHPLC]

Resin based Systems (Analytical to Process scale)

[Bioseparation Biopurification]

Special Tools to improve data quality, reproducibility and productivity

[Inert RSA  Glass Vials]

Method & Material  Choices  1

[Knowledge Education]
[Sample  Preparation]
[Reverse_Phase_LC]
[Adsorption-LC RPC & SPE]
[AQ Columns]
[Phenyl Bond Columns]
[FPF_Columns]
[HILIC & Aq. Norm. Phase]
[Electrostat. Repul. HILIC]
[Normal Phase Chromatography]

Process Scale   Chromatography Equipment

[Process  Chromatogr.]
[Process Chromat.Systems]
[Flash &  MPLC Pumps]
[HPLC  Pumps]
[Special  Pumps]
[Fraction Collectors]
[Stainless Steel Columns]
[Glass  Columns]
[Glass  Cartridges]
[Plastic Cartridges]
[Manual  Valves]
[Motor  Valves]
[Efficiency  Tools]

Method & Material Choices 

[Knowledge Education]
[Multi  Mode LC]
[Chiral  Chromatography]
[Ion Exchange  & Ion LC]
[Hydrophobic  Interaction LC.]
[Affinity  LC]
[Size Exclusion Chromatogr.]
[SuperCritical Fluid LC]
[Proteomics]
[Metabolomics]
[Process  Scale LC]
[Kamasutra Inspired Tech]