Imtakt Column

IMTAKT is strong on design, development and production of highly innovative and unique HPLC columns for solving complex separation problems

IMTAKT operates from two sites, - Imtakt Corporation  co-founded by Itaru Yazawa is located in historic Kyoto, Japan and IMTAKT USA is located in Philadelphia, USA. Mr. Yazawa developed HPLC columns for YMC and instruments for Schimadzu for more than 20 years before founding Imtakt .

Their Product range as follows:

New

World's first amino acid analysis column for LC-MS (55 Amino Acids in 10 Min!)

 

Multi-Mode-Reverse Phase columns (to separate Anion, Cation, Neutral compounds)

Scherzo Range

High resolution, non-porous 2 um reverse phase columns ( for Peptides, Proteins, Bio- or Synthetic- Polymers)

Wide-pore, low polarity reverse phase columns (to separate Proteins )

 

 

High resolution  low pressure reverse phase columns with different selectivity

  • Cadenza Range
  • Cadenza CD-C18
  • Cadenza 5CD-C18
  • Cadenza CL-C18
  • Cadenza 5Cl-C18
  • Cadenza HS- C18
  • Cadenza CW-C18

High resolution, traditional reverse phase columns

  • Unison UK Range
  • Unison UK - C18
  • Unison UK - C8
  • Unison UK - Pheny
  • Unison UK - Silica
  • Unison UK - Amino

 

Properties of Product range

Column Name

Column Type

USP Code

Particle Size()

Pore Size (nm)

Ciolumn Lengths (mm)

Column Int. Diameters (mm)

Scherzo SW-C18

Reverse Phase - Normal Phase & Ion Exchange

L1

3

13

10 - 500

0.075 - 28.0

Scherzo SM-C18

Reverse Phase - Normal Phase& Ion Exchange

L1

3

13

10 - 500

0.075 - 28.0

Scherzo SS-C18

Reverse Phase - Normal Phase& Ion Exchange

L1

3

13

10 - 500

0.075 - 28.0

Presto FF-C18

Reverse Phase

L1

2

NA

10 - 250

0.075 - 4.6

Intrada WP-RP

Reverse Phase

N/A

3

30

10 -150

075 - 10

Intrada Amino Acid

Special phase for amino acid

 

3

 

10 - 250 

3, 2, 1, 0.5 - 0.075

Cadenza CD-C18

Reverse Phase

L1

3

12

10 - 500

0.075 - 10.0

Cadenza 5CD-C18

Reverse Phase

L1

5

12

10 - 250

0.075 - 28.0

Cadenza CW-C18

Reverse Phase

L1

3

30

10 - 500

0.075 - 10.0

Cadenza CL-C18

Reverse Phase

L1

3

12

10 - 500

0.075 - 10.0

Cadenza HS-C18

Reverse Phase

L1

3

12

10 - 500

0.075 - 10.0

Unison UK-C18

Reverse Phase

L1

3

13

10 - 500

0.075 - 10.0

Unison UK-C8

Reverse Phase

L7

3

13

10 - 500

0.075 - 10.0

Unison UK-Phenyl

Reverse Phase

L11

3

13

10 - 500

0.075 - 10.0

Unison UK-Silica

Normal Phase

L3

3

13

10 - 500

0.075 - 10.0

Unison UK-Amino

Normal Phase & Ion Exchange

L8

3

NA

10 - 500

0.075 - 10.0

Unison US-C18

Reverse Phase

L1

5

13

10 - 250

0.075 - 28.0


Scherzo Product Range

Become a specialists in Multi Mode Chromatography!

Most pharmaceutical molecules have apolar, polar and ionic domains that can be utilised to achieve high resolution and robust chromatograms. Multi-mode chromatography phases carry a number of different moieties to address the various domains and to arrive at better separation results.  In our Know-how section we describe how you can become a specialist in this new fast advancing technology. please click here

Scherzo SW-C18

Surface chemistry

IMTAKT Scherzo SW-C18 surface

Low density of strong anionic,  cationic and reverse phase C18 ligands.

Applications

  • Simultaneous analysis of both cationic and anionic compounds in RP and  Ion Exchange separation mode
  • For polar compounds
  • LC-MS compatible without using ion-pair reagents
  • Neurotransmitters in the Striatum Tissues

Select the most appropriate from a broad range of Application Notes

Scherzo SM-C18

Surface chemistry

IMTAKT Scherzo SM-C18 surface

Applications

  • Multi-mode: anion exchange, cation exchange, reverse phase and normal phase

Select the most appropriate from a broad range of Application Notes

Scherzo SS-C18

Surface chemistry

IMTAKT Scherzo SS-C18 surface

 

High density of strong cationic and anionic ligands as well as C18 ligands

Applications

Select the most appropriate from a broad range of Application Notes

 

Presto Product Range

Presto FF-C18

Features

Applications

  • Consists of C18 bonded to monodispersed 2um non-porous silica.
  • Useful for both biopolymer and synthetic polymer separations.

 

Intrada Product Range

Intrada WP-RP

Features

Applications

  • Wide pore Reversed-phase for proteins and other large molecules,
  • High recovery of proteins,
  • Optimal structure polarity for faster polymer elution

Intrada Amino Acid Column (New)

Worlds first and very best Amino Acid column that is solely focussed on intact amino acid separation

  • Very Fast LC - MS Analysis of Amino Acids
  • Most competitively priced and unique Amino Acid column in the market
  • Amino Acid Separation without sample derivatisation (no pre - and post labeling necessary!)
  • Ability to separate isobaric amino acids such as Leu and Ile
  • High throughput (<1 minute) analysis for selected amino acids
  • 5 - 10 min. for standard amino acids analysis
  • Long life

Application & Brochures

Imtakt Amino Acid by LC-MS TR06AE

Imtakt Amino Acid  Instruction Mannual IM-WAA

Imtakt Tech Infomation 20 Standard Amino Acid TI737E

Imtakt Tech Information 20 Amino Acid Chromatogram TI735E

Imtakt Tech Information 50 Amino Acids TI734E

Imtakt Tech Information Amino Acids in Soy Sauce  TI736E

 

Cadenza Product Range

Cadenza CD-C18

Surface Chemistry

Applications

IMTAKT Cadenza CD C18 chromatogram

 

  • For superior high through put analysis
  • High resolution,
  • Low pressure,
  • Best with hydrophobic compounds,
  • Molecular recognition, Multicomponent separation

 

Cadenza 5CD-C18

Applications

  • High resolution,
  • pH stable,
  • Best with hydrophobic compounds,
  • Molecular recognition, Multicompenant separation

Cadenza CL-C18

Surface Chemistry

IMTAKT Cadenza CL-c18

Applications

  • Silanol regulation

 

Cadenza 5Cl-C18

Applications

 

Cadenza HS- C18

Surface Chemistry

IMTAKT Cadenza HS C18

Applications

  • Serum/plasma direct injection,
  • Different selectivity

 

Cadenza CW-C18

Surface Chemistry

Applications

Excellent peak shape for basic drug compounds and antibiotics, High-throughput, Low pressure

Back to top

 

Unison Product Range

Unison series are HPLC columns for low to high polarity compound separation. The column is filled with 3 um high purity silica particles modified with octadecyl groups.

The column provides high speed analytical test results , low solvent consumption, high resolution and wide range of pH stability.

Star-up condition

Injection sample and eluent must be filtered through 0.2 um or 0.45 um porous filter to avoid column’s pressure increase.

LC Instrument set up:

To achieve maximum column performance , LC System should be set-up as follows:

  • Set peak response of detector and data processing software to maximum level for high speed analysis time (within two minutes)
  • Minimize length of tubing between injector-to-column and column-to-detector
  • When flow rate is low (e.g. 0.2ml/min), semi-micro LC system system is recommended
  • For gradient elution, a binary pump with small mixing chamber should be used

Process Conditions:

Eluent:

  • A general eluent comprises a mixture of methanol or Acetonitrile
  • Ionic solute analysis: A suitable pH modifier should be added into eluent such as TFA, acetic acid or phosphate buffer
  • Solvent: Use only HPLC grade of solvents

 Flow Rate:

  • Flow rate settings depend on column length and ID, elution time, system pressure and column temperature.
  • Standart flow rate for 4,6 mll/nin. wtef 5 un particles. If column length is longer than 15 cm fkow rate should be set lower (e.g. 0.2 ml/min to avoid exceeding the maximum pressure
  • Recommended Flow rates:
    • 1 mm ID= 0.03 - 0.2 mlmin
    • 1.5 mm ID = 0.05 - 0.3 ml/min
    • 2 mm ID = 0.1 - 0.6 ml/min
    • 3 mm ID =  0.2 - 1.0 ml/min
    • 4.6 mm ID = 0.5 - 2.0 ml/min
    • 10 mm ID = 2 - 4 ml/min 
  • High pressure columns are avail able for higher flow rates (HT and UP versions)

Pressure Limits

  • The operating maximum pressure for this column is
  • approx. 25 MPa for 3 um particles
  • HT Col Type: approx. 50MPa for 3 um particles
  • UP Col Type approx. 100 MPa for 3 um particles
  • approx. 15 MPa for 10 um particles - 28 mm ID.Column.

Column Temp

  • Operating temp is 15 - 65 C
  • Column Temp should be set considering reproducibility of retention, separation and peak shape

pH

  • The usual pH range for this column is between 2 to 7
  • After high alkali operation change eluent to storing solvent to increase column life

Column Storing Solvent

  • Initial Solvent is inspection solvent
  • The column should be stored at room temperature filled with approx 60 % Acetonitrile /40% Water or 70 % Methanol/ 30% distilled Water and have tightly screwed end plugs.
  • Please do not allow the column to dry out under any circumstances

Unison UK - C18

Applications

  • Best with polar compounds,
  • Separation balance,
  • No phase collapse with 100% aqueous eluent

 

Unison US - C18

Applications

  • Best with polar compounds,
  • Separation balance,
  • No phase collapse with 100% aqueous eluent

 

Unison UK - C8

Applications

  • Best with polar compounds and basic compounds. ,
  • No phase collapse with 100% aqueous eluent

 

Unison UK - Phenyl

Applications

  • High resolution,
  • Low pressure,
  • Best with hydrophobic compounds,
  • Molecular recognition, Multicompenant separation

 

Unison UK - Silica

Applications

  • Aqueous to non-aqueous Normal phase

 

Unison UK - Amino

Applications

  • Revolutionary aqueous durability for aminopropyl phase,
  • Aqueous to non-aqueous Normal Phase Separation

 

© by LCC 1995 -2016 All rights reserved
 Chromatographyshop is a division of LCC Engineering & Trading GmbH, CH-4622 Egerkingen, Switzerland.
Collaboration partners in various countries
Our Company Profile and Summary Product List 2015
Unser Firmenprofil und Produktzusammenfassung 2015
      Our Terms and Conditions

Sample Preparation Tools

[Sample  Preparation]
[MatrixEx]
[QuEChERS]
[SPE]
[Syringe Filters]
[Inert RSA  Glass Vials]
[Flash Chromatography]

General Issues

[Chromatogr. Shop Home]
[Newsletter Archive]
[Our Services & Company]
[Terms & Conditions]
[Mobile Phone]

 Bonuses for you

[Special Deals for you]

Seminars & Workshops

[Knowledge Education]
[Seminars & Workshops]

Analytical Scale Chromatography

[Analytical Columns]
[ACE & ACE  Excel Columns]
[ACE Ultra Core]
[Microsolv Cogent Column]
[Capcell Shiseido]
[Daicel / Chiral Technologies]
[GL Science  Inertsil]
[Hichrom Columns]
[Imtakt Column]
[Kromasil Akzo Nobel]
[Mitsubishi MCI-Gel]
[Merck Lichro...]
[Macherey &  Nagel]
[Princeton  Chromatography]
[PolyLC  Columns]
[SieLC Primesep]
[Capcell Shiseido]
[Ultron by Shinwa]
[Welch  Materials]
[Zirchrom]
[Agilent Zorbax]

Knowledge Tools for Chromatographers

[Knowledge Education]
[Definition of  Terms Used]
[Separation Mechanism]
[Solvent  Selection]
[Buffers for  LC.]
[Column &  Material Care]
[Prep & Process Columns]
[Analytical  Columns]
[HPLC- to-UHPLC]

Resin based Systems (Analytical to Process scale)

[Bioseparation Biopurification]

Special Tools to improve data quality, reproducibility and productivity

[Inert RSA  Glass Vials]

Method & Material  Choices  1

[Knowledge Education]
[Sample  Preparation]
[Reverse_Phase_LC]
[Adsorption-LC RPC & SPE]
[AQ Columns]
[Phenyl Bond Columns]
[FPF_Columns]
[HILIC & Aq. Norm. Phase]
[Electrostat. Repul. HILIC]
[Normal Phase Chromatography]

Process Scale   Chromatography Equipment

[Process  Chromatogr.]
[Process Chromat.Systems]
[Flash &  MPLC Pumps]
[HPLC  Pumps]
[Special  Pumps]
[Fraction Collectors]
[Stainless Steel Columns]
[Glass  Columns]
[Glass  Cartridges]
[Plastic Cartridges]
[Manual  Valves]
[Motor  Valves]
[Efficiency  Tools]

Method & Material Choices 

[Knowledge Education]
[Multi  Mode LC]
[Chiral  Chromatography]
[Ion Exchange  & Ion LC]
[Hydrophobic  Interaction LC.]
[Affinity  LC]
[Size Exclusion Chromatogr.]
[SuperCritical Fluid LC]
[Proteomics]
[Metabolomics]
[Process  Scale LC]
[Kamasutra Inspired Tech]