MTAKT operates from two sites, - Imtakt Corporation  co-founded by Itaru Yazawa is located in historic Kyoto, Japan and IMTAKT USA is located in Philadelphia, USA. Mr. Yazawa developed HPLC columns for YMC and instruments for Schimadzu for more than 20 years before founding Imtakt .

IMTAKT focusses on design, development and production of highly innovative and unique HPLC column for solving complex separation problems

They structure the Product range as follows:

Multi-Mode-Reverse Phase column to separate Anion, Cation, Neutral compounds

High resolution, non-porous 2um reverse phase columns for Peptides, Proteins, Bio- or Synthetic- Polymers

Wide-pore, low polarity reverse phase columns Protein

High resolution  low pressure reverse phase columns with different selectivity

  • Cadenza Range
  • Cadenza CD-C18
  • Cadenza 5CD-C18
  • Cadenza CL-C18
  • Cadenza 5Cl-C18
  • Cadenza HS- C18
  • Cadenza CW-C18

High resolution , traditional reverse phase columns

  • Unison UK Range
  • Unison UK - C18
  • Unison UK - C8
  • Unison UK - Pheny
  • Unison UK - Silica
  • Unison UK - Amino


Product Propertie

Column Name

Column Type

USP Code

Particle Size(µ)

Pore Size (nm)

Lengths (mm)

Internal Diameters (mm)

Scherzo SW-C18

Reverse Phase - Normal Phase & Ion Exchange

L1

3

13

10 - 500

0.075 - 28.0

Scherzo SM-C18

Reverse Phase - Normal Phase& Ion Exchange

L1

3

13

10 - 500

0.075 - 28.0

Scherzo SS-C18

Reverse Phase - Normal Phase& Ion Exchange

L1

3

13

10 - 500

0.075 - 28.0

Presto FF-C18

Reverse Phase

L1

2

NA

10 - 250

0.075 - 4.6

Intrada WP-RP

Reverse Phase

N/A

3

30

10 -150

075 - 10

Cadenza CD-C18

Reverse Phase

L1

3

12

10 - 500

0.075 - 10.0

Cadenza 5CD-C18

Reverse Phase

L1

5

12

10 - 250

0.075 - 28.0

Cadenza CW-C18

Reverse Phase

L1

3

30

10 - 500

0.075 - 10.0

Cadenza CL-C18

Reverse Phase

L1

3

12

10 - 500

0.075 - 10.0

Cadenza HS-C18

Reverse Phase

L1

3

12

10 - 500

0.075 - 10.0

Unison UK-C18

Reverse Phase

L1

3

13

10 - 500

0.075 - 10.0

Unison UK-C8

Reverse Phase

L7

3

13

10 - 500

0.075 - 10.0

Unison UK-Phenyl

Reverse Phase

L11

3

13

10 - 500

0.075 - 10.0

Unison UK-Silica

Normal Phase

L3

3

13

10 - 500

0.075 - 10.0

Unison UK-Amino

Normal Phase & Ion Exchange

L8

3

NA

10 - 500

0.075 - 10.0

Unison US-C18

Reverse Phase

L1

5

13

10 - 250

0.075 - 28.0

 

Scherzo Family

Scherzo SW-C18

Scherzo SM-C18

Scherzo SS-C18

Multi-Mode

Reversed Phase + Anion Exchange + Cation Exchange

Scherzo family columns can operate without adding an ion-pairing reagent which is required for conventional ODS columns. In addition, both anionic and cationic compounds are retained on this column. The hydrophobicity of the Scherzo family is similar to that of a conventional ODS column, so analysis of a compound in combination with a Unison UK-C18 column (conventional ODS phase) will be very effective for method development.

Applications

  • Consists of a lower density of strong anionic and cationic ligands as well as C18 ligands.
  • Simultaneous analysis of both cationic and anionic compounds in RP and  Ion Exchange separation mode
  • For polar compounds L
  • C-MS compatible without using ion-pair reagents

 
IMTAKT Scherzo SW-C18 Ligand

IMTAKT Scherzo SM-C18 Ligand
IMTAKT Scherzo SS-C18 Ligand

Large amount of strong ionic ligands loaded onto this ODS column. Effective for improved retention of zwitterions or weak ionic compounds

Weak ionic ligands adequately loaded onto this ODS column. Designed for separation of basic / acidic compounds at neutral pH condition

Low amount of strong ionic ligands loaded onto this ODS column. Effective for strong ionic compound elution or basic compounds with formic acid eluent

Retention properties of multi-mode ODS, Scherzo family

You can find the best HPLC conditions by optimizing salt concentration or pH to improve retention / separation for ionic compounds, which is difficult on a conventional ODS column.

Scherzo Salt

For the Scherzo multi-mode ODS column, optimizing the salt concentration is as important as optimizing the organic solvent. In the left figure, retention of both anionic and cationic compounds are decreased when salt concentration is increased. At the same salt concentration, SSC18, which consists of a large amount of strong ionic ligands, retains strongly. SM-C18 , with weak ionic ligands has medium retention. And finally, SW-C18, which has a low amount of strong ionic ligands, shows the lowest retention.

Scherzo pH

pH is also an important factor for the elution of ionic compounds. Retention will be dramatically changed between neutral pH (ammonium acetate or formate) and low pH (formic acid) conditions. SS-C18 and SW-C18 consist of strong ionic ligands and retention will be increased under low pH conditions. On the other hand, SM-C18 consists of weak ion ligands which cannot ionize at a low pH -therefore, retention of basic compounds will be decreased due to a decrease in ionization capacity at low pH.

Back to top

 

Presto FF-C18

Features

  • World's first non-porous high resolution ODS column.
  • Non-Porous 2 µm ODS-Silica
  • Reversed-phase mode for polymers up to 30 MDa
  • Separates almost any polymer including bio-polymers and synthetic polymers
  • Amazing number of peaks for peptides and proteins
  • Different selectivity from porous ODS columns
  • 250mm length high-resolution column with 2um particle
  • High-efficiency with low flow rate compatible with conventional HPLC systems

Applications

  • polyethylene glycol (ca.20 kDa)
  • DNA, (ca. 30 MDa)
  • Monoclonal IgG (mAb, ca.150 kDa)
  • Hyaluronic acid (ca. 1 MDa)
  • Polyvinylpyrrolidone (ca.50 kDa)
  • Very useful for protein analysis especcially peptide mapping or IgG (mAb) as follows:
  • Recommended condition are ....
    1) Lower flow rate than porous columns
    2) Shallow gradient like several %B in 120min
    3) Do not use single pump (low pressure) gradient, but binary pump with T-union (no mixer) gradient is recommended
     

Examples

Presto Peptide Mapping

Amazing separations for many molecular weights from peptides to proteins. Presto FF-C18, a non-porous ODS HPLC column, performs exceptionally well with peptide separations. HPLC and LC-MS analysis of a small amount of peptides is important for proteomics. Presto FF-C18 can achieve twice as many peaks as conventional porous ODS columns. Non-porous ODS Presto FF-C18 may change the proteomics field dramatically.

A: water /TFA = 100 /0.1, B: acetonitrile /TFA = 100 /0.1,  50 deg.C, 220nm , Tryptic digest of alpha-casein, 5uL, Presto FF-C18 (2um), 250 x 4.6 mm, 1-35%B (0-150min), 0.4mL/min (25MPa), Porous ODS (3um), 250 x 4.6 mm, 5-45% B (0-150min), 1mL/min (14MPa),

Presto Monoclonal Antibody

Immunoglobulin G (IgG), a large protein (MW ca. 150kDa), can exhibit poor peak shape when injected onto porous RP columns, due to high mass transfer resistance. Non-porous ODS Presto FF-C18 can provide improved peak shape and recognition between mAb (same amino acid sequence) and polyclonal antibody (different amino acid sequence). Presto FF-C18 may change the antibody separation field, which has had difficulty using traditional porous columns.

Tech Brochure Presto FF C18

Cadenza CD C18 vs Presto FF C18

 


Intrada WP-RP

Features:

  • Reversed-Phase Column for Polymer Separation
  • Reversed-phase tailored with a 30nm pore size
  • Optimal for the separation of proteins and other large molecules
  • Superior Resolution Column with 3um Particles
  • High resolution 3um Silica is used
  • Radically improved column efficiency compared with conventional 5um columns
  • Optimal Structure Polarity for Faster Polymer Elution
  • Uses a newly developed reversed-phase ligand
  • Highly hydrophobic polymer elution made possible by optimal surface polarity
  • Key specifications: 3um particle size, 30nm pore size, special ligand for reversed-phase, polymeric end- capping

Brochure Intrada

High Resolution Separation of 111 Proteins ( 9-225 kDa )

New proteomic analytical method called the fluorescent labeled protein method using Intrada WP-RP (Courtesy of Professor Emeritus Imai, University of Tokyo, Japan). The 3um particular, 500mm column provides the ability to separate large numbers of proteins.

Intrada 111 Proteins

Back to top

 

Cadenza Family

 

 

 

 

IMTAKT Cadenza CL-C18 Ligand

Cadenza CD-C18

Molecular recognition

Multicomponent separation

Applications

  • For superior high throgh put analysis
  • High resolution,
  • Low pressure,
  • Best with hydrophobic compounds,
  • Molecular recognition, Multicomponant separation
IMTAKT Cadenza CL-C18 Ligand

Cadenza 5CD-C18

Applications

  • High resolution,
  • pH stable,
  • Best with hydrophobic compounds,
  • Molecular recognition, Multicompenant separation
IMTAKT Cadenza CL-C18 Ligand

Cadenza CL-C18

Cadenza 5CL-C18

Contrast CD-C18

Silanols regulation

 

Applications

  • Silanol regulation
IMTAKT Cadenza HS C18 Ligand

Cadenza HS-C18

Serum/plasma direct injection

Different selectivity

 

Applications

  • Serum/plasma direct injection,
  • Different selectivity

 

Cadenza CW-C18

High-throughput

Basic compounds

Applications

Excellent peak shape for basic drug compounds and antibiotics, High- through put, Low pressure

High Through Put Analysis

Cadenza CD C18 chromatogram

High Through Put High Pressure Brochure Cadenza CD-C18

Back to top

 


Unison UK - C18

Features

Applications

  • Best with polar compounds,
  • Separation balance,
  • No phase collapse with 100% aqueous eluent

Unison US - C18

Features

Applications

  • Best with polar compounds,
  • Separation balance,
  • No phase collapse with 100% aqueous eluent

Unison UK - C8

Features

Applications

  • Best with polar compounds and basic compounds. ,
  • No phase collapse with 100% aqueous eluent

Unison UK - Phenyl

Features

Applications

  • High resolution,
  • Low pressure,
  • Best with hydrophobic compounds,
  • Molecular recognition, Multicompenant separation

Unison UK - Silica

Features

Applications

  • Aqueous to non-aqueous Normal phase

Unison UK - Amino

Features

Applications

  • Revolutionary aqueous durability for aminopropyl phase,
  • Aqueous to non-aqueous Normal Phase Separation